Data center aisle containment

Control the aisle. Plan the whole system.

BOLEIN builds cold and hot aisle containment around the way your data hall is laid out. From cabinets and roof sections to doors, cable routes and controls, each part has a place in the project specification.

The physical layer matters

Containment is a room decision, not a cabinet accessory.

Airflow depends on more than where the racks stand. The roof must meet the aisle width; doors must work with the circulation route; gaps around cabinets, cable entries and overhead services need a coordinated plan. BOLEIN brings these components together so the enclosure system can be specified as one build.

Air pathChoose which aisle to contain based on cooling supply and return.
Physical fitMatch row length, cabinet heights, ceiling clearance and room obstructions.
OperationPlan door access, lighting, monitoring and fire-system interfaces early.
Start with the airflow strategy

Cold aisle or hot aisle?

Both approaches create a physical separation between equipment intake air and exhaust air. The choice comes from the room’s cooling architecture, return path, existing racks and installation constraints.

01 / COLD AISLE CONTAINMENT

Keep supply air at the equipment intake.

Enclose the aisle facing the front of the racks. End doors and roof sections help define the path from the cooling supply to the server inlets. This is often considered when the cooling design delivers air into the aisle.

Cooling supply→Contained aisle→Rack intake

Design review: supply location, floor or overhead delivery, aisle width, door traffic and roof coordination.

02 / HOT AISLE CONTAINMENT

Collect exhaust air behind the racks.

Enclose the aisle at the rear of the equipment and coordinate the warm-air return route with the room cooling design. Roof and door details depend on how exhaust air is taken back to the cooling system.

Rack exhaust→Contained aisle→Return path

Design review: return-air path, overhead clearance, service conditions inside the aisle and fire-system requirements.

Containment hardware does not replace a cooling design. Final configuration should be coordinated with the facility’s airflow and fire protection plans.

Installed cold aisle with two rows of cabinets and glazed roof sections
Built around the row

Start with the cabinets. Finish every opening.

Cabinet alignment defines the aisle; roof modules and end doors complete its boundary. Cable entry, bridging panels and blanking pieces close the practical gaps that a clean rendering can hide.

  • Cabinet row: height, width, depth, load and equipment access
  • Roof: fixed and operable skylight sections to suit the design
  • Ends: automatic sliding or manual door options
  • Edges: end panels, infill and blanking panels around transitions
See the component plan →
Configure the complete aisle

Every component has a job to do.

The exact bill of materials varies by room. These are the elements BOLEIN can discuss when turning a concept into a coordinated containment package.

01 / ENCLOSURE

Define the boundary

  • Network cabinets19-inch enclosures, doors, side panels and mounting space.
  • Fixed roof sectionsGlazed or solid roof areas placed to suit the aisle layout.
  • Operable roof sectionsOpenable skylight modules where the project design calls for them.
  • Blanking & infill panelsClose unused spaces and transitions around the row.
02 / ACCESS & CONTROL

Make the aisle usable

  • Automatic sliding doorsEnd-of-aisle access with a planned opening route.
  • Manual door optionsAlternative entrance formats for the operating pattern.
  • Alarm & displayAudible or visual alerts and status display options.
  • Ambient lightingLighting integrated with the aisle design.
03 / INTEGRATION

Coordinate what crosses it

  • Top trunking & cable ladderOrganized overhead paths for data cabling.
  • Fire control interface boxSpace and interface to coordinate with the approved fire strategy.
  • Cable entry & sealingRoute services while managing openings in the boundary.
  • Cabinet accessoriesPDU, shelves and mounting rails selected per rack.
Project reference / air-cooled aisle

Inside a 7.5 m aisle: 26 cabinets and four precision cooling units.

This project combined a 26-cabinet row with four precision air-conditioning units inside the aisle. The detail that makes it more than a standard rack layout is the enclosure around it: three 600 mm roof-module types, including a fixed metal section made to wrap around a column, plus a controlled sliding entrance and the cable, fire-control and display components specified for the aisle.

7,500 mmaisle length
2647U cabinets, 600 × 1200 mm
4precision air-conditioning units inside the aisle
52side doors, 47U × 1200 mm
Design details
01 / ROW & COOLING

The aisle is built around the equipment.

Twenty-six 47U floor-standing cabinets form the row. The specification also calls for 52 side doors in 1.2 mm sheet metal and four precision air-conditioning units inside the 7.5 m aisle.

02 / ROOF & ROOM FIT

One roof, three kinds of module.

The 600 mm roof package includes sheet-metal fixed sections, acrylic operable skylights and sheet-metal fixed sections formed around a column. Aisle blanking panels complete the listed enclosure scope.

03 / ACCESS & SERVICES

More than an end door.

The automatic sliding door set includes a door housing and standard access control. Ambient lighting, a display screen, fire control box and M-type cable trunking are part of the project configuration.

Configuration at a glance

Cabinet row26 × 47U floor-standing cabinets, each 600 × 1200 mm; 52 × 47U × 1200 mm side doors, 1.2 mm thick.
In-aisle coolingFour precision air-conditioning units configured inside the 7,500 mm air-cooled aisle.
Roof & infill600 mm sheet-metal fixed roof; 600 mm acrylic operable skylight; 600 mm column-wrap sheet-metal fixed roof; aisle blanking panels.
EntranceOne automatic sliding door set with door housing, standard access control and ambient lighting.
Control & cableFire control box, display screen and M-type cable trunking.
Rack power24-outlet C13 rack PDU configuration.
Optional700 mm heavy-duty shelf and 700 mm L-shaped mounting rails.

Project data provided by BOLEIN. The shelf and rails are optional. The separate rendering below illustrates a containment concept and does not depict this project.

BOLEIN project case / hot aisle containment

A hot aisle layout built around changing row ends.

BOLEIN supplied a hot-aisle containment package for a data center with several row-end layouts. Different end-door arrangements, cabinet infill and an overhead cable route around a building column were brought into one coordinated package.

One end configuration uses a 3.6 m automatic double sliding-door assembly for a 1.2 m aisle passage. Other ends use different door and infill modules, matched to the cabinet rows they close.

Illustrative rendering of BOLEIN hot-aisle containment with glazed sliding end doors, roof panels and an overhead cable route around a column
Illustrative rendering based on the supplied project drawings. It is not a site photograph or exact room plan.
01 / ACCESS

Doors matched to each end.

The design includes automatic sliding-door variants with transparent panels, access-control provisions and safety sensors. The end assemblies vary with the row layout.

02 / ROOM FIT

Enclosure around real obstructions.

Different panel widths close the spaces beside cabinet rows. A purpose-designed cable tray passes around a structural column while maintaining the overhead route.

03 / INTERFACES

Control planned into the package.

The specified control boxes provide a 12 V fire-signal interface and two-color ambient-light control. The drawings also show access-control and exit-button positions at the doors.

Visualize the full aisle

See the system before final specification.

A dual-row cold aisle brings cabinet alignment, overhead cable routing, fixed and glazed roof sections, and sliding end doors into one coordinated layout. The concept makes it easier to review access and service paths before detailed dimensions and interfaces are confirmed.

For a live project, BOLEIN can work from your rack schedule and room drawings to discuss module layout and accessory selection.

Prepare a Project Brief →
Illustrative rendering of a dual-row cold aisle with roof panels, overhead cable routes and sliding end doors
Illustrative cold aisle concept. Final project design and equipment configuration may differ.
Engineering conversation

What has to be decided before a quotation?

A useful containment quote is tied to a room and a rack plan. These inputs determine whether the doors, roof, services and controls can be specified coherently.

01 / ROOM

Floor plan & clearances

Room dimensions, column positions, ceiling height, obstructions and access route.

02 / RACKS

Row schedule

Rack count, height, width, depth, equipment load and any unequal-height units.

03 / AIRFLOW

Supply & return

Cold or hot aisle concept, floor or overhead supply, return path and target aisle width.

04 / INTERFACES

Doors, roof & services

Door mode, fixed or operable roof, cable ladder, lighting, alarm, display and fire interface.

If some details are still open, send the current drawing and mark the unknowns. The next step is to review the configuration with your project team.

Real equipment and production

From fabricated frame to installed aisle.

The system must work on the shop floor and in the data hall. These views show cabinet assembly, production capacity and a completed aisle environment.

Installed cabinet aisle with equipment and overhead structure
Installed aisle environment and service access.
Rows of network cabinet frames during assembly
Cabinet frames prepared for assembly.
Metal fabrication workshop with cabinet components
Metal fabrication and cabinet components.
Inside and around the rack

Complete the infrastructure around the containment.

The aisle package connects to the rack-level choices your operators will use every day.

01 / CABINETS

19-inch enclosures

Choose equipment space, door and panel format, rail positions and static load to suit each row. Confirm the cabinet configuration against the equipment schedule and access plan.

02 / RACK POWER

PDU options

Specify the PDU input, outlet type, mounting format and quantity for each rack. Custom intelligent configurations can be discussed when monitoring or control is required.

03 / ACCESSORIES

Shelves, rails & cable paths

Specify mounting rails, shelves, cable management and blanking pieces with each rack so accessories fit the equipment and remain accessible after installation.

Project path

Move from room drawing to a buildable list.

01

Share the room

Send layout, rack schedule and cooling concept.

02

Set the aisle

Confirm containment type, dimensions and door access.

03

Coordinate interfaces

Review roof, cable routes, controls and accessories.

04

Confirm the package

Agree the component list and project-specific specification.

Common project questions

Before the first drawing review.

Can BOLEIN supply both cold and hot aisle containment?

Yes. The enclosure strategy, roof and return path are discussed against the facility cooling concept.

Can the roof combine fixed and operable sections?

Yes. The module plan depends on aisle length, overhead services and fire-system coordination.

Are automatic sliding doors available?

Yes. Automatic and manual door formats can be considered; final access and control details are project-specific.

Can controls and lighting be included?

Alarm, ambient lighting, displays and fire control interface boxes can be discussed as part of the system configuration.

What if the cabinet heights are different?

Send the rack schedule and elevations. Transitions and infill should be reviewed before the roof and panel list is fixed.

Can PDUs and rack accessories be quoted together?

Yes. Include outlet type, input, mounting location, shelf loads and rail requirements in the project list.

Start the specification

Bring us the room. We will discuss the aisle.

Send your current layout, rack count and cooling concept. Even an early-stage drawing is enough to start identifying the roof, door, cable and control decisions that belong in the scope.

01 / DRAWING

Room plan

Dimensions, elevations, ceiling and access route.

02 / EQUIPMENT

Rack schedule

Count, sizes, load and accessory requirements.

03 / OPERATIONS

Cooling & interfaces

Supply, return, doors, roof, alarm and fire coordination.

Request a Project Quote ↗