LAN cables for the links you are building.
Choose BOLEIN Cat6, Cat6A or Cat7 bulk cable by conductor, shielding, jacket and installation environment. Find a model that fits your cable schedule, then send us the quantities for a quote.
Category illustrationStart with the run, then choose the construction.
A cable route determines more than length. Match the category and screening to your network design, then check conductor material, jacket and packaging against the installation specification.
Unshielded cable for planned copper runs.
BOLEIN Cat6 UTP options include pure-copper and copper-clad aluminium conductors. A pure-copper outdoor-jacket model is also available. Choose the construction specified for the job.
Choose unshielded or individually screened pairs.
Cat6A options include UTP and U/FTP structures with solid bare-copper conductors and light grey LSZH jackets.
Screened construction for specified links.
The Cat7 S/FTP option combines pair screening and an outer braid in an orange LSZH jacket. Check the complete channel design before ordering.
Bring the cable schedule to the enquiry.
Send the installation requirements with your model choice so conductor and jacket details can be checked against the project specification.
- Category and structure · Cat6, Cat6A or Cat7; UTP, U/FTP or S/FTP.
- Conductor · Identify whether the specification calls for bare copper. Copper-clad aluminium is confined to the Cat6 models identified below.
- Route and jacket · State indoor or outdoor use and the jacket required by the project.
- Order quantity · Provide total cable length or the number of 305 m boxes or drums.
Compare the models.
Use the construction fields to narrow the range, then confirm the selected cable against your cable schedule.
| Model | Category / screen | Conductor | Jacket / use | Pack |
|---|---|---|---|---|
| BLC-4PGR-C6 | Cat6 UTP | 23 AWG solid bare copper | Light grey PVC | 305 m box |
| BLEC-4PGR-C6 | Cat6 UTP | 23 AWG solid CCA | Grey PVC | 305 m box |
| BLEC-4PBL-C6 | Cat6 UTP | 23 AWG solid CCA | Dark blue PVC | 305 m box |
| BLC-4PBK-C6 | Cat6 UTP | 23 AWG pure copper | Black PE + PVC · outdoor | 305 m drum |
| BLC-4PGR-ULC6A | Cat6A UTP | 23 AWG solid bare copper | Light grey LSZH | 305 m drum |
| BLC-4PGR-FLC6A | Cat6A U/FTP | 23 AWG solid bare copper | Light grey LSZH | 305 m drum |
| BLC-4PGR-SFLC7 | Cat7 S/FTP | 23 AWG solid bare copper | Orange LSZH | 305 m drum |
CCA = copper-clad aluminium. Confirm permitted conductor material and any required test documentation for the destination project before ordering.